Search results for "computer vision"
showing 10 items of 2353 documents
Restricted compositions and permutations: from old to new Gray codes
2011
Any Gray code for a set of combinatorial objects defines a total order relation on this set: x is less than y if and only if y occurs after x in the Gray code list. Let @? denote the order relation induced by the classical Gray code for the product set (the natural extension of the Binary Reflected Gray Code to k-ary tuples). The restriction of @? to the set of compositions and bounded compositions gives known Gray codes for those sets. Here we show that @? restricted to the set of bounded compositions of an interval yields still a Gray code. An n-composition of an interval is an n-tuple of integers whose sum lies between two integers; and the set of bounded n-compositions of an interval si…
Promotion et Développement d'un Master Erasmus Mundus - L'Exemple du VIBOT
2011
Cet article decrit l’offre de formation a l’internationale proposee au Centre Universitaire Condorcet du Creusot (Universite de Bourgogne) dans le domaine de la vision par ordinateur et de la robotique. Il presente l’organisation particuliere de ces formations et les actions de support mises en place pour en assurer la perennite.
Computational volumetric reconstruction of integral imaging with improved depth resolution considering continuously non-uniform shifting pixels
2018
Abstract In this paper, we propose a new computational volumetric reconstruction technique of three-dimensional (3D) integral imaging for depth resolution enhancement by using non-uniform and integer-valued shifting pixels. In a typical integral imaging system, 3D images can be recorded and visualized using a lenslet array. In previous studies, many computational reconstruction techniques such as computational volumetric reconstruction and pixel of elemental images rearrangement technique (PERT) have been reported. However, a computational volumetric reconstruction technique has low visual quality and depth resolution because low-resolution elemental images and uniformly distributed shiftin…
Integral-Imaging display from stereo-Kinect capture
2017
In this paper, we propose a new approach in order to improve the quality of microimages and display them onto an integral imaging monitor. Our main proposal is based on the stereo-hybrid 3D camera system. Originally, hybrid camera system has dissimilarity itself. We interpret our method in order to equalize the hybrid sensor's characteristics and 3D data modification strategy. We generate integral image by using synthetic back-projection mapping method. Finally, we project the integral image onto our proposed display system. We illustrate this procedure with some imaging experiments in order to prove an advantage of our approach.
Binocular function measures as predictors of user performance in stereoscopic augmented reality
2021
Inconsistency between the binocular and focus cues in stereoscopic augmented reality overburdens the visual system leading to its stress. However, a high individual variability of tolerance for visual stress makes it difficult to predict and generalize the user gain associated with the implementation of alternative visualization technologies. In this study, we investigated the relationship between the binocular function and perceptual judgments in augmented reality. We assessed the task completion time and accuracy of perceptual distance matching depending on the consistency of binocular and focus cues in the stereoscopic environment of augmented reality. The head-mounted display was driven…
B-Scan image analysis for position and shape defect definition in plates
2016
Definition of size, shape and location of defects into a mechanical component is of extreme importance in the manufacturing industry in general and particularly in high-tech applications, and in applications that can become dangerous due to the structural failure of mechanical components. In this paper, a laser-UT system has been used to define position and shape of internal defects in aluminum plates. An infrared pulsed laser is used to generate ultrasonic waves in a point of the plate and a CW laser interferometer is used as receiver to acquire the out-of-plane displacements due to the ultrasonic waves in another point of the plate. The method consists of acquiring a B-Scan map on which s…
A procedure for slicing and characterizing soft heterogeneous and irregular-shaped tissue
2020
Abstract This paper presents a slicing technique useful to prepare precise and repeatable samples from organs which are irregularly shaped and highly heterogeneous for mechanical testing and advanced microscopy observation. The suggested technique does not seem to influence the internal microstructure and it is employed here for testing specimens cut from different region of the meniscal tissue. Fast Fourier Transform analysis is used to quantify characteristic features of the microstructure (collagen fibers orientation, pore size) after slicing prior mechanical testing. Uniaxial (relaxation) tests are performed on dog-bone meniscal samples. Stress relaxation testing results on samples cut …
Integral imaging with Fourier-plane recording
2017
Integral Imaging is well known for its capability of recording both the spatial and the angular information of threedimensional (3D) scenes. Based on such an idea, the plenoptic concept has been developed in the past two decades, and therefore a new camera has been designed with the capacity of capturing the spatial-angular information with a single sensor and after a single shot. However, the classical plenoptic design presents two drawbacks, one is the oblique recording made by external microlenses. Other is loss of information due to diffraction effects. In this contribution report a change in the paradigm and propose the combination of telecentric architecture and Fourier-plane recordin…
Mass calibration of the energy axis in ToF- E elastic recoil detection analysis
2016
We report on procedures that we have developed to mass-calibrate the energy axis of ToF-E histograms in elastic recoil detection analysis. The obtained calibration parameters allow one to transform the ToF-E histogram into a calibrated ToF-M histogram.
Evaluation of the Colorimetric Performance of Single-Sensor Image Acquisition Systems Employing Colour and Multispectral Filter Array
2015
International audience; Single-sensor colour imaging systems mostly employ a colour filter array (CFA). This enables the acquisition of a colour image by a single sensor at one exposure at the cost of reduced spatial resolution. The idea of CFA fit itself well with multispectral purposes by incorporating more than three types of filters into the array which results in multispectral filter array (MSFA). In comparison with a CFA, an MSFA trades spatial resolution for spectral resolution. A simulation was performed to evaluate the colorimetric performance of such CFA/MSFA imaging systems and investigate the trade-off between spatial resolution and spectral resolution by comparing CFA and MSFA …